Electrocardiographs, electromyographs, and electroencephalographs are medical devices that monitor the electrical activity of the heart, muscles, and brain by measuring the potential differences on the surface of living tissues. These tools play a crucial role in diagnosing various physiological conditions. However, clinicians often encounter several practical challenges when performing biopotential measurements. This article aims to discuss these issues and provide effective solutions to improve measurement accuracy and patient comfort.
ECGs, EMGs, and EEGs measure the electrical activity of the heart, muscles, and brain respectively. These signals are generated due to the movement of ions across cell membranes during nerve stimulation and muscle contraction. To capture these weak bioelectric signals, biopotential electrodes are used. The quality of the signal depends heavily on the electrode-skin contact, which is often overlooked but critical for accurate readings.
One of the common problems faced by medical professionals is improper skin preparation before electrode placement. If the skin is not cleaned or dried properly, it can lead to poor conductivity, resulting in noisy or unreliable data. Additionally, factors such as age, race, and skin condition can affect the impedance levels between the electrode and the skin. For instance, gold electrodes used in ECG systems may have higher impedance compared to silver/silver chloride electrodes commonly found in EMG and EEG setups.
In clinical environments, interference from other medical equipment—such as ablation devices, electric cautery units, defibrillators, pacemakers, and external pacing systems—can significantly impact the accuracy of biopotential measurements. These sources of noise must be carefully managed to ensure clear and reliable data collection.
To address these challenges, careful system design and advanced electronic components are essential. Signal conditioning circuits with high input impedance and low noise performance can greatly enhance the reliability of biopotential measurements. For example, junction field effect transistor (JFET) input operational amplifiers like the AD8625/AD8626/AD8627 family offer extremely low input bias current—less than 1 pA—which minimizes electrode polarization and improves signal integrity.
Similarly, the AD8220 and AD8224 instrumentation amplifiers feature input bias currents below 20 pA, making them ideal for sensitive biopotential applications. These devices are also designed to operate over a wide supply voltage range, allowing them to function effectively in challenging environments such as emergency rooms and operating theaters where power supplies may be unstable.
The AD8625/AD8626/AD8627 series operates from a single 5V to 26V power supply, while the AD8220 and AD8224 can run on either a dual ±18V supply or a single 5V supply. Both offer rail-to-rail output and a large dynamic range, ensuring high-quality signal processing. Their low quiescent current—750 μA for the AD8220 and AD8224—makes them suitable for battery-powered systems, offering flexibility and portability in clinical settings.
In addition, the AD8224 can be configured as a single-channel differential output amplifier, providing excellent noise immunity and making it a versatile choice for complex biopotential monitoring systems. By integrating such advanced components into the design, clinicians can achieve more accurate, stable, and efficient biopotential measurements, ultimately improving patient care and diagnostic outcomes.