When using closed-loop control in hoisting mechanisms, regardless of the inverter brand, if an encoder cannot be added, it's essential to systematically check the following issues. Make sure each point is verified and resolved: 1. The slot port for the encoder card may not be correctly selected, especially in multi-slot inverters. 2. The encoder card itself might be faulty or damaged. 3. Incorrect wiring could be a problem—check the power polarity, phase sequence, and whether the drive voltage matches the encoder’s requirements. 4. The encoder body could be damaged or malfunctioning. 5. During factory shipping, internal wiring of the encoder might have been incorrectly set up. 6. If the encoder lead-out wire isn’t properly grounded during installation, it may cause grounding issues or contact with the casing. 7. Poor crimping or loose connections between the encoder cable and terminal blocks can lead to signal loss or short circuits. 8. A broken wire within the encoder cable could disrupt the signal entirely. 9. The encoder pulse count might be incorrect, leading to inaccurate feedback. 10. If the encoder is not securely fastened, vibrations or misalignment can cause signal distortion and faults. 11. Improper identification of driver power supply or phase sequence when connecting the encoder cable to external cables can result in wiring errors. It's crucial to approach these issues methodically, ensuring that every component from the encoder to the inverter is checked and properly configured.